Libros importados con hasta 50% OFF + Envío Gratis a todo USA  Ver más

menú

0
  • argentina
  • chile
  • colombia
  • españa
  • méxico
  • perú
  • estados unidos
  • internacional
portada Airflow and Indoor Air Quality Models of DOE References Commercial Buildings (en Inglés)
Formato
Libro Físico
Idioma
Inglés
N° páginas
162
Encuadernación
Tapa Blanda
Dimensiones
28.0 x 21.6 x 0.9 cm
Peso
0.39 kg.
ISBN13
9781499159790

Airflow and Indoor Air Quality Models of DOE References Commercial Buildings (en Inglés)

Andrew K. Persily (Autor) · Steven J. Emmerich (Autor) · Lisa C. Ng (Autor) · Createspace Independent Publishing Platform · Tapa Blanda

Airflow and Indoor Air Quality Models of DOE References Commercial Buildings (en Inglés) - Persily, Andrew K. ; Emmerich, Steven J. ; Ng, Lisa C.

Libro Físico

$ 11.99

$ 14.99

Ahorras: $ 3.00

20% descuento
  • Estado: Nuevo
Se enviará desde nuestra bodega entre el Viernes 28 de Junio y el Lunes 01 de Julio.
Lo recibirás en cualquier lugar de Estados Unidos entre 1 y 3 días hábiles luego del envío.

Reseña del libro "Airflow and Indoor Air Quality Models of DOE References Commercial Buildings (en Inglés)"

Sixteen reference buildings have been defined by the U.S. Department of Energy, and created as EnergyPlus input files, for use in assessing new technologies and supporting the development of energy codes in pursuing building energy efficiency improvements. Infiltration rates in the EnergyPlus models of the reference buildings were input as constant airflow rates, and not calculated based on established building airflow theory. In order to support more physically-based airflow calculations, as well as indoor air quality analysis, models of the 16 reference buildings were created in the multizone airflow and contaminant transport program CONTAM. A number of additional inputs had to be defined for the CONTAM models, and changes in the interior zoning were required, to more realistically account for airflow. Annual airflow and contaminant simulations were performed in CONTAM for six of the buildings. While the assumed infiltration rates in EnergyPlus do not realistically reflect impacts of weather conditions, there are clear relationships between the outdoor air change rates calculated by CONTAM and weather. In addition, the envelope airtightness values assumed in either approach are seen to have a major impact on the air change rates. Contaminant analyses were performed for occupant-generated carbon dioxide, volatile organic compounds from indoor sources, outdoor particulate matter, and outdoor ozone. The airflow and contaminant calculation results provide a useful baseline for subsequent use of these models to investigate approaches to building ventilation and other technologies that are intended to simultaneously reduce building energy consumption while maintaining or improving indoor air quality.

Opiniones del libro

Ver más opiniones de clientes
  • 0% (0)
  • 0% (0)
  • 0% (0)
  • 0% (0)
  • 0% (0)

Preguntas frecuentes sobre el libro

Todos los libros de nuestro catálogo son Originales.
El libro está escrito en Inglés.
La encuadernación de esta edición es Tapa Blanda.

Preguntas y respuestas sobre el libro

¿Tienes una pregunta sobre el libro? Inicia sesión para poder agregar tu propia pregunta.

Opiniones sobre Buscalibre

Ver más opiniones de clientes